


{"id":13085,"date":"2016-10-17T08:49:20","date_gmt":"2016-10-17T14:49:20","guid":{"rendered":"https:\/\/www.barcodesinc.com\/news\/?p=13085"},"modified":"2016-11-17T12:01:19","modified_gmt":"2016-11-17T18:01:19","slug":"customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features","status":"publish","type":"post","link":"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/","title":{"rendered":"Customize Your Imager&#8217;s Scanning Using Honeywell&#8217;s Centering, Aimer Delay, and CodeGate Features"},"content":{"rendered":"<p><img decoding=\"async\" loading=\"lazy\" class=\"\" src=\"https:\/\/cdn.barcodesinc.com\/images\/models\/lg\/Honeywell\/xenon-1900-black.jpg\" alt=\"\" width=\"129\" height=\"244\" align=\"right\" \/>With all <a href=\"https:\/\/www.barcodesinc.com\/cats\/barcode-scanners\/imager.htm\">imager based scanners<\/a>, the default decode mode is the full area of the decode window, so it will decode whatever barcode it sees first. This makes it difficult sometimes to target a specific barcode when the barcodes are close together.\u00c2\u00a0 We can help using the below features:<\/p>\n<ul>\n<li><strong>Centering<\/strong>(AKA pick list mode or center decode): This feature narrows the scanner\u00e2\u20ac\u2122s field of view to make sure the scanner reads only those barcodes intended by the operator.<\/li>\n<li><strong>Aimer Delay<\/strong>:\u00c2\u00a0 Turns on the aimer for a split second before the scanner scans. This allows time for the operator to position the scanner over the specific barcode before the barcode is scanned.<\/li>\n<li><strong>CodeGate<\/strong>:\u00c2\u00a0 Similar to Aimer Delay except the aiming beam is on all the time, but scanner won\u00e2\u20ac\u2122t scan until scanner button is pressed or specific time passes.<\/li>\n<\/ul>\n<p><!--more--><\/p>\n<p><strong>Example multi-barcode label<\/strong><\/p>\n<p><a href=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/example.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-13086\" src=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/example.jpg\" alt=\"example\" width=\"298\" height=\"183\" srcset=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/example.jpg 531w, https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/example-300x184.jpg 300w\" sizes=\"(max-width: 298px) 100vw, 298px\" \/><\/a><\/p>\n<ol>\n<li>Open Word. With scanner returned to Factory Defaults, scan the \u00e2\u20ac\u0153supplier\u00e2\u20ac\u009d barcode ten times in row &amp; count the number of times you actually got the correct barcode VE5042X0.\u00c2\u00a0 Move the scanner to your hip before each scan.<\/li>\n<\/ol>\n<ol start=\"2\">\n<li>Turn on <strong>Centering<\/strong> by scanning this centering configuration barcode. Repeat\/count ten scans.<br \/>\n<a href=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/bc1.gif\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-13184 size-full\" src=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/bc1.gif\" alt=\"\" width=\"62\" height=\"62\" \/><\/a><\/li>\n<\/ol>\n<ol start=\"3\">\n<li>Turn on <strong>Aimer Delay<\/strong> by scanning this barcode.\u00c2\u00a0 It programs a \u00c2\u00bd second aimer delay.\u00c2\u00a0 Aimer Delay time is completely programmable.\u00c2\u00a0 Repeat the exercise.<br \/>\n<a href=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/bc2.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-13185 size-full\" src=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/bc2.png\" alt=\"\" width=\"46\" height=\"46\" \/><\/a><\/li>\n<\/ol>\n<ol start=\"4\">\n<li>Turn on<strong> CodeGate <\/strong>and repeat the exercise.<br \/>\n<a href=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/bc3.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-13186 size-full\" src=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/bc3.png\" alt=\"\" width=\"244\" height=\"133\" \/><\/a><\/li>\n<\/ol>\n<ol start=\"5\">\n<li>When you are done, scan the CodeGate off barcode.\u00c2\u00a0 Factory Default barcode currently does not turn off CodeGate.<br \/>\n<a href=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/bc4.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-13187 size-full\" src=\"https:\/\/www.barcodesinc.com\/news\/wp-content\/uploads\/2016\/10\/bc4.png\" alt=\"\" width=\"220\" height=\"127\" \/><\/a><\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>With all imager based scanners, the default decode mode is the full area of the decode window, so it will decode whatever barcode it sees first. This makes it difficult sometimes to target a specific barcode when the barcodes are close together.\u00c2\u00a0 We can help using the below features: Centering(AKA pick list mode or center [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[2,224,56],"tags":[1089,501,1879,938,1878,1880,98,301],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Customize Your Imager&#039;s Scanning Using Honeywell&#039;s Centering, Aimer Delay, and CodeGate Features - Barcoding News<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Customize Your Imager&#039;s Scanning Using Honeywell&#039;s Centering, Aimer Delay, and CodeGate Features - Barcoding News\" \/>\n<meta property=\"og:description\" content=\"With all imager based scanners, the default decode mode is the full area of the decode window, so it will decode whatever barcode it sees first. This makes it difficult sometimes to target a specific barcode when the barcodes are close together.\u00c2\u00a0 We can help using the below features: Centering(AKA pick list mode or center [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/\" \/>\n<meta property=\"og:site_name\" content=\"Barcoding News\" \/>\n<meta property=\"article:published_time\" content=\"2016-10-17T14:49:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-11-17T18:01:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cdn.barcodesinc.com\/images\/models\/lg\/Honeywell\/xenon-1900-black.jpg\" \/>\n<meta name=\"author\" content=\"BarcodesInc\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"BarcodesInc\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/\",\"url\":\"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/\",\"name\":\"Customize Your Imager's Scanning Using Honeywell's Centering, Aimer Delay, and CodeGate Features - Barcoding News\",\"isPartOf\":{\"@id\":\"https:\/\/www.barcodesinc.com\/news\/#website\"},\"datePublished\":\"2016-10-17T14:49:20+00:00\",\"dateModified\":\"2016-11-17T18:01:19+00:00\",\"author\":{\"@id\":\"https:\/\/www.barcodesinc.com\/news\/#\/schema\/person\/4887305f61b70f8fa89a8ca7343ec6d4\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.barcodesinc.com\/news\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Product News\",\"item\":\"https:\/\/www.barcodesinc.com\/news\/category\/product-news\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Customize Your Imager&#8217;s Scanning Using Honeywell&#8217;s Centering, Aimer Delay, and CodeGate Features\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.barcodesinc.com\/news\/#website\",\"url\":\"https:\/\/www.barcodesinc.com\/news\/\",\"name\":\"Barcoding News\",\"description\":\"Barcode, Auto-ID, Point of Sale and RFID News\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.barcodesinc.com\/news\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.barcodesinc.com\/news\/#\/schema\/person\/4887305f61b70f8fa89a8ca7343ec6d4\",\"name\":\"BarcodesInc\",\"sameAs\":[\"http:\/\/www.barcodesinc.com\"],\"url\":\"https:\/\/www.barcodesinc.com\/news\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Customize Your Imager's Scanning Using Honeywell's Centering, Aimer Delay, and CodeGate Features - Barcoding News","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/","og_locale":"en_US","og_type":"article","og_title":"Customize Your Imager's Scanning Using Honeywell's Centering, Aimer Delay, and CodeGate Features - Barcoding News","og_description":"With all imager based scanners, the default decode mode is the full area of the decode window, so it will decode whatever barcode it sees first. This makes it difficult sometimes to target a specific barcode when the barcodes are close together.\u00c2\u00a0 We can help using the below features: Centering(AKA pick list mode or center [&hellip;]","og_url":"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/","og_site_name":"Barcoding News","article_published_time":"2016-10-17T14:49:20+00:00","article_modified_time":"2016-11-17T18:01:19+00:00","og_image":[{"url":"https:\/\/cdn.barcodesinc.com\/images\/models\/lg\/Honeywell\/xenon-1900-black.jpg"}],"author":"BarcodesInc","twitter_card":"summary_large_image","twitter_misc":{"Written by":"BarcodesInc","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/","url":"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/","name":"Customize Your Imager's Scanning Using Honeywell's Centering, Aimer Delay, and CodeGate Features - Barcoding News","isPartOf":{"@id":"https:\/\/www.barcodesinc.com\/news\/#website"},"datePublished":"2016-10-17T14:49:20+00:00","dateModified":"2016-11-17T18:01:19+00:00","author":{"@id":"https:\/\/www.barcodesinc.com\/news\/#\/schema\/person\/4887305f61b70f8fa89a8ca7343ec6d4"},"breadcrumb":{"@id":"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.barcodesinc.com\/news\/customize-imagers-scanning-using-honeywells-centering-aimer-delay-codegate-features\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.barcodesinc.com\/news\/"},{"@type":"ListItem","position":2,"name":"Product News","item":"https:\/\/www.barcodesinc.com\/news\/category\/product-news\/"},{"@type":"ListItem","position":3,"name":"Customize Your Imager&#8217;s Scanning Using Honeywell&#8217;s Centering, Aimer Delay, and CodeGate Features"}]},{"@type":"WebSite","@id":"https:\/\/www.barcodesinc.com\/news\/#website","url":"https:\/\/www.barcodesinc.com\/news\/","name":"Barcoding News","description":"Barcode, Auto-ID, Point of Sale and RFID News","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.barcodesinc.com\/news\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.barcodesinc.com\/news\/#\/schema\/person\/4887305f61b70f8fa89a8ca7343ec6d4","name":"BarcodesInc","sameAs":["http:\/\/www.barcodesinc.com"],"url":"https:\/\/www.barcodesinc.com\/news\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.barcodesinc.com\/news\/wp-json\/wp\/v2\/posts\/13085"}],"collection":[{"href":"https:\/\/www.barcodesinc.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.barcodesinc.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.barcodesinc.com\/news\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.barcodesinc.com\/news\/wp-json\/wp\/v2\/comments?post=13085"}],"version-history":[{"count":3,"href":"https:\/\/www.barcodesinc.com\/news\/wp-json\/wp\/v2\/posts\/13085\/revisions"}],"predecessor-version":[{"id":13183,"href":"https:\/\/www.barcodesinc.com\/news\/wp-json\/wp\/v2\/posts\/13085\/revisions\/13183"}],"wp:attachment":[{"href":"https:\/\/www.barcodesinc.com\/news\/wp-json\/wp\/v2\/media?parent=13085"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.barcodesinc.com\/news\/wp-json\/wp\/v2\/categories?post=13085"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.barcodesinc.com\/news\/wp-json\/wp\/v2\/tags?post=13085"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}