Bosch - B5512 WITH TRANSFORMER AND SMALL ENCLOSU
  • Provides up to 48 points using a combination of hardwired or wireless points for installation flexibility and up to 4 areas with perimeter and interior control
  • Installer-friendly features for simple installation and communications, including plug-in PSTN and cellular communication modules
  • Programmable keypad shortcuts, situation sensitive on-screen help, and a bilingual user interface make system operation simple and easy
Read More
$261.34
Add to Quote
Bosch Parts Accessory Model Overview
Products and parts from Bosch.
Bosch B5512-D Security Camera Overview
The B5512 Control Panel integrates intrusion and residential fire, providing one simple user interface for both systems. The B5512 provides up to 48 individually identified points that can be split into 4 areas.

The control panel can communicate through its built-in Ethernet port (not applicable to "E" control panels), or through compatible plug-in modules that can send events over the public switched telephone network (PSTN) or over cellular network communications. With the B5512, you can monitor doors, windows, and motion within areas like showrooms or those that hold inventory. Each user can have a personalized passcode, a wireless keyfob, and an access credential to control the system.

Use programmable authority levels with restricted privileges to provide service, security, and cleaning personnel with full or limited access. Use the three programmable outputs (expandable up to 43) to turn on lights or lock and unlock doors. Users can:
  • Turn on the system to secure the stockroom while you conduct daily business.
  • Perform tests to ensure your system is working properly.
  • Set your system to alarm immediately if a door opens.
  • Activate the Watch feature so a tone sounds whenever a customer enters.
  • Set a schedule for your system to automatically turn on at closing time.
  • Use wireless security options to customize your system.
Central monitoring stations provide 24-hour system monitoring with access to vital services. Professional security personnel can test the system, monitor system activity, and alert the police, fire department, or other emergency response teams if necessary.

Programmable outputs
  • Three programmable on-board outputs; one high current using a relay, and two trigger outputs
  • Output A, with a contact rating of 3 Amps, can supply up to 1.0 A total current from AUX PWR
  • Outputs B and C sink up to 50 mA at 12 VDC
  • Four alarm-output patterns
  • Programmable bell test
Point response
  • 20 custom point profiles
  • Selectable point response time
  • Cross point capability
  • Fire alarm verification
  • Dangerous gas indicator includes carbon monoxide (NFPA 720)
  • Watch mode
User interface
  • Supervision of up to 8 keypads
  • Custom keypad text is fully programmable through RPS or the Installer Services Portal programming tool (available in Europe, Middle East, Africa, and China)
  • Full function menu including custom functions
  • Authority by area and 32 character name for each user
  • 14 custom authority levels to restrict system features that each user can access
  • Programmable primary and secondary language by user and keypad
  • 9 available languages
User interface languages

The following table shows the available languages per keypad type.

Area configurations

Link multiple areas to a shared area such as a lobby or common entryway. The shared area then automatically turns On (arms) when all associate areas are armed and turns Off (disarms) when any one associate area is disarmed. For higher security applications, the Area Re-Arm feature guarantees that areas are always rearmed, and are disarmed for no longer than a specific, configurable, amount of time (for example, service time).
Technical Information
Number of Standard Zones:
48
Number of Relays Supported:
43
Number of Events Log:
255
User Code Storage:
50
Network & Communication
Sensor Connectivity:
  • Hardwired
  • Wireless
Ethernet:
Yes
Battery Information
Battery Voltage:
12 V DC
Power Description
Input Voltage:
18 V AC
Miscellaneous
Package Contents:
  • B5512 IP Control Panel, 48 Points
  • 1 x Literature Pack
    • UL Installation Guide
    • ULC Installation Guide (English and French)
    • Owner's Manual Release Notes
    • SIA Quick Reference Guide
  • 1 x Quick Installation Guide
  • 1 x Literature CD Containing Product Literature
  • 1 x Wiring Label for Enclosure Door
  • 1 x Hardware Pack:
    • Mounting Clips
    • 1 kΩ EOL Resistors
    • Battery Wires
    • 4 x #6 x 3/4 in Self Threading Screws
Certifications & Standards:
  • ANSI-SIA
    • CP-01-2010-Control Panel Standard - Features for False Alarm Reduction
  • RCM
    • ACMA
  • CE
    • EMC, LVD, RoHS [B6512, B5512, B4512, B3512]
  • UL
    • Underwriters Laboratories
    • UL 365 - Police Station Connected Burglar Alarm Units
    • UL 609 - Standard for Local Burglar Alarm Units and Systems
    • UL 636 - Holdup Alarm Units and Systems
    • UL 985 - Household Fire Warning System Units (6th edition)UL 1023 - Household Burglar Alarm System Units
    • UL 1076 - Proprietary Burglar Alarm Units and Systems
    • UL 1610 - Central Station Burglar Alarm Units
    • UL 1635 - Standard for Digital Alarm Communicator System Units
  • CSFM
  • FCC Part 15 Class B
    • Part 15 Class B
  • ULC
    • Underwriters Laboratories of Canada S1871-20121210
    • CAN/ULC S303 - Local Burglar Alarm Units and Systems
    • CAN/ULC S304 - Standard for Signal Receiving Center and Premise Burglar Alarm
    • CAN/ULC S545 - Residential Fire Warning System Control Units
    • CAN/ULC S559 - Fire Signal Receiving Centres and Systems
    • ULC-ORD C1023 - Household Burglar Alarm System Units
    • ULC-ORD C1076 - Proprietary Burglar Alarm Units and Systems
  • IC
    • ICES-003 - Information Technology Equipment (ITE)
  • ANATEL
    • 04712-16-01855
Environmentally Friendly:
Yes
Country of Origin:
China
Get help from a Barcoding Expert!